MIL-L-48063A(MI)
4.3.2.3 Tube, assembly (see dwg. 356AS170 covering a detail of
dwg. 356AS1OO.
Categories
Defects
Method of Inspection
Critical:
None defined,
Major:
AQL 1.00 percent
101.
Missing parts or loose or im-
proper assembly of contact . . . . . . . . . . Visual
102.
Missing parts or loose or im-
proper assembly of detent . . . . . . . . . . . . . . . Visual
103.
Stop missing, loose or impro-
perly assembled . . . . . . . . . . . . . . . . . . . . . . . . . . . Visual
104.
Length from detent lock to
contact arm . . . . . . . . . . . . . . . . . . . . . . . . . . . Gage
105.
Distance detent rocket locking
tang projects into
tube (min. ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Gage
Minor:
AQL 1.00 percent
201.
Contact arm mobility . . . . . . . . . Visual/Mech.
202.
Evidence of poor workmanship
(see 3.7) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Visual
4.3.2.4 Tube, assembly, weldment - 1 and 2.
(see dwg. 356AS189
covering a detail of dwg. 356AS1OO).
Categories
Defects
Method of Inspection
Critical:
None defined.
Major:
AQL 0.65 percent
101.
Angle of center of aft
bulkhead stop with longitudinal
axis of contact arm as
applicable . . . . . . . . . . . . . . . . . . . . . . . . . . Visual
102.
Length of bulkhead stop . . . . . . . . . . . . . Gage
Missing parts or welds. . . . . . . . . . . . Visual
103.
14
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business