MIL-L-48063A(MI)
Ten (10) launchers as follows:
a.
(1) All-Initial Examination (4.4.14.1).
(2) Two (2) in accordance with High Temperature , (4.4.14.2), Low
Temperature, (4.4.14.3), and Static Load, (4.4.14.9).
(3) Two (2) in accordance with Vibration, (4.4.14.6), and Static
Firing, (4.4.14.10).
(4) Two (2) in accordance with Flight Firing, (4.4.14.11).
(5) Two (2) in accordance with Shock, (4.4.14.5), and Static Firing,
(4.4.14.10).
(6) Two (2) in accordance with Salt Fog, (4.4.14.8), and Rough
Handling, (4.4.14.7).
b.
Twelve (12) intervalometers as follows:
(1) ALL in accordance with Electrical Tests, (4.4.6).
(2) ALL in accordance with Simulated Firing Test, (4.4.7).
(3) ALL in accordance with Bypass Test, (4.4.8).
(4) Two (2) in accordance with Humidity, (4.4.9.1).
(5) Two (2) in accordance with Sand and Dust (4.4.9.2).
(6) Two (2) in accordanca with Shock, (4.4.9.3).
(7) Two (2) in accordance with Salt Fog, (4.4.9.4).
(8) Two (2) in accordance with Acceleration, (4.4.9.5).
(9) Two (2) in accordance with Life, (4.4.9.6).
c. Eight (8) additional intervalometers, when intervalometers are
being procured separately, as follows:
(1) ALL in accordance with Electrical Tests, (4.4.6).
(2) ALL in accordance with Simulated Firing Test, (4.4.7).
(3) ALL in accordance with Bypass Test, (4.4.8).
(4) Four (4) in accordance with High Temperature, (4.4.9 .-) and Low
Temperature, (4.4.9.8).
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business