MIL-T-60916C(MI)
Classification of defects, integral bulkhead motor tube (continued).
TABLE V.
4.7.2 Integral bulkhead motor tube, 2.75 inch FFAR (see drawing 1569403
and table VI) .
TABLE VI.
Classification of defects, integral bulkhead motor tube.
4.8
Testing.
4.8.1 Bearing surface evaluation test (see drawing 1569403, note 6B).
A sample consisting of one motor tube shall be taken from a period not greater
than four hours of production. The sample shall be tested as specified in
4.9.1. Any bearing surface reduced greater than that allowed in note 6B of
drawing 1569403 shall be considered defective.
Each defective tube shall
cause rejection of the units produced since the last acceptable tube was
inspected.
4.8.2 Hydrostatic test (see drawing 1569403, note 2). This test shall
be performed before the inspection in paragraph 4.7.1, 100 percent as
specified in 4.9.2.
Any tube that does not conform to the requirements shall