MIL-DTL-85769B(AS)
TABLE II. First article inspection.
Treatment or test
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 Test
paragraph
Visual
x x x x x x x x x x x x x x x x x x 4.5.1
X-ray and circuit
x x x x x x x x x x x x x x x x x x 4.5.2,
resistance
4.5.3
High temperature
x x x x x x x x x x 4.5.4.1
storage
X-ray and circuit
xx
x
x
x
x
x
x
x
x
4.5.2,
resistance
4.5.3
Temperature
x
x
x
x
x
x
x
x
4.5.4.2
shock
X-ray and circuit
x
x
x
x
x
x
x
x
4.5.2,
resistance
4.5.3
Salt fog
x
x
4.5.4.3
Vibration
4.5.4.3
@ -40° F
x
x
x
@ 140° F
x
x
x
X-ray and circuit
x
x
x
x
x
x
4.5.2,
resistance
4.5.3
Two-foot drop
x
x
4.5.4.5
X-ray and circuit
x
x
4.5.2,
resistance
4.5.3
Acceleration
xx
4.5.4.6
firings
Ballistic test
4.5.5
@ -40° F
xxx
x
x
x
x
x
@ 140° F
xxx
x
x
x
x
x
4.4.3 Classification of characteristics. The characteristics verified by the tests and
examinations herein are classified as critical, major, or minor in accordance with DOD-STD-
2101. Requirements that verify critical characteristics are identified by the symbol (C) and
major characteristics by the symbol (M). The number following the classification symbol
indicates the serial number of the requirement. Requirements not annotated with a classification
code are classified minor.